- Rotation sensing system
using a non-contact sensor
- ML sensor corresponding to
an option other than the input
Display: 0 to 99999 Red LED
Accuracy : ± 0.01% + 1digit at23 ℃ ± 5 ℃
The gap sensor : 0.3Vp-p ~ 12Vp - p 0.5Hz ~ 15kHz
Open Collector : +12 V 1mHz ~ 50kHz
Square wave : Hi: 4 ~ 30V
Lo: 0 ~ 2V 1mHz ~ 50kHz
Output Current : DC4 ~ 20mA
Output cycle : 100msec
Display cycle : 0.1, 0.5 , 1, 2, 3, 4 , 5 sec
Set the operation cycle display settings
Compare settings : HI, LO, OFF mode switch is set to
Setting range: 0 to 99999
How to: Compare the way up and down four points independent
Comparison output: relay contact output AL1 ~ AL4 each
30,000 Cycles Electrical Life 1c contacts
Contact capacity : AC250V 0.2A resistive load
DC30V 0.2A resistive load
GOOD on start: This function is available when
LO of alarm is set. LO does
not operate when power switch on
Key protection parameters and set off comparison output
Off function : key operation has been terminated after the time setting display
Power: AC Type : AC85 ~ 250V 50/60Hz
DC type : DC16 ~ 32V
Sensor power : DC12V ± 10% 40mA
Operating ambient temperature : 0 ~ 50 ℃
Size and weight : 96W × 48H × 105D (mm): approx 300g