AEC-37Series
- DPU-50A·60A·80A·100A
- - DPU-50A
- DPU-60A
- DPU-80A
- DPU-100A
- Model name : DPU-50A
Measuring range : 0 ~ 25mm (α0: mm)
Output Voltage : ± 5V (1.5mm / V)
Suitable transducer : 3750 37MS-50
Resolution : 12 ㎛ -
Linearity : ± 0.5% / FS (2.5 to 22.5 mm of measuring distance)
± 3% / FS (other measuring distance)
Temperature range : - 20 ℃ ~ +80 ℃
Temperature characteristics : ± 0.01% / ℃ of drift between -20 ℃ and +80 ℃
Model name : DPU-60A
Measuring range : 0 ~ 30mm (α0: mm)
Output Voltage : ± 5V (mm / V)
Suitable transducer : 3760 37MS-60
Resolution : 15 ㎛ -
Linearity : ± 0.5% / FS (3 to 27 mm of measuring distance)
± 3% / FS (other measuring distance)
Temperature range : - 20 ℃ ~ +80 ℃
Temperature characteristics : ± 0.01% / ℃ of drift between -20 ℃ and +80 ℃
Model name : DPU-80A
Measuring range : 0 ~ 40mm (α0: mm)
Output Voltage : ± 5V (mm / V)
Suitable transducer : 3780 37MS-80
Resolution : 20 ㎛ -
Linearity : ± 0.5% / FS (4 to 36 mm of measuring distance)
± 3% / FS (other measuring distance)
Temperature range : - 20 ℃ ~ +80 ℃
Temperature characteristics : ± 0.01% / ℃ of drift between -20 ℃ and +80 ℃
Model name : DPU-100A
Measuring range : 0 ~ 50mm (α0: mm)
Output Voltage : ± 5V (1mm / V)
Suitable converter : 37100 37MS-100
Resolution : 25 ㎛ -
Linearity : ± 0.5% / FS (5 to 45 mm of measuring distance)
± 3% / FS (other measuring distance)
Temperature range : - 20 ℃ ~ +80 ℃
Temperature characteristics : ± 0.01% / ℃ of drift between -20 ℃ and +80 ℃